GENERAL FEATURES

These are some general paragraphs that are use to clarify and supplement the TRICOIL® specifications.

ENHANCED HUMIDITY CONTROL SYSTEM

Where specified or where indicated on the drawings, provide an enhanced humidity control system as described herein. The base bid system shall be the patented TRICOIL® method of air conditioning for enhanced temperature and humidity control. The TRICOIL® components shall be furnished as a coordinated package by the air handling unit manufacturer. Contact Sensible Equipment Company, P.O. Box 669, Goldenrod, Florida 32733, telephone number (407) 296 - 8068, Fax Number (407) 296 - 7420.

Alternates to the base bid are encouraged. The contractor may furnish, with the engineers approval, a deductive alternate to the base bid to use other equipment or methods that provides performance as scheduled. Alternate bids must be submitted in writing with complete engineering analysis including equipment performance data, psychrometric analysis with chart, flow diagrams, equipment specifications, manufacturer's descriptive literature, reduction in bid amount, and other information required by the engineer to analyze the proposed alternate. The alternate must include any and all costs for the work of other trades required to provide complete and operational equivalent systems. The contractor shall assume single source responsibility for all the subsystems that he chooses to integrate and submit for his alternate bid. All responsibilities for equivalencies for the performance of the alternate system or method to the base bid system or method plus the coordinated supporting central plant utilities (electrical and/or mechanical) plant shall constitute a required single source responsibility and shall be so acknowledged by the contractor with the alternate proposal.

The air handling units shall have the following features:

TRICOIL® METHOD KITS FOR FIELD ASSEMBLY

The TRICOIL® method is a recuperative wrap around type system providing simultaneous precooling and reheat for temperature and humidity control. The TRICOIL® method shall also provide heating and supplemental reheat control where indicated. The TRICOIL® method Kits include components which shall be field assembled and wired by the installing contractor. The TRICOIL® method Kits shall consist generally of the following components:

TRICOIL® METHOD PUMP/VALVE ASSEMBLIES

The TRICOIL® method is a recuperative wrap around type system providing simultaneous precooling and reheat for temperature and humidity control. The TRICOIL® method shall also provide heating and supplemental reheat control where indicated. The TRICOIL® method components shall be provided for field installation and wiring by the installing contractor. The TRICOIL® method components shall consist generally of the following:

PUMPS FOR KITS AND ASSEMBLIES

The pump shall be an In-line type or In-line Booster type as scheduled or other approved. Pump characteristics shall be as scheduled on the drawings.

VALVES FOR KITS AND ASSEMBLIES

The valves used in the TRICOIL® system shall be of the type as scheduled or other approved. Characteristics shall be as scheduled on the drawings.